Search:  
 
      

 

Programming and Use Instructions for the Med Reminder PC100

** NOTE: Revised instructions for changing batteries in PC100 **

En Espaņol Instrucciones

Operating Systems Supported
Windows 95/98/ME/XP and Windows NT4.0/2000

Setup
Insert Software CD that accompanied this product into the CD-ROM drive of your computer. Setup should launch automatically. If this does not happen, click Start>Run. Then type x:\Setup, where "x" is the drive letter of your CD-ROM. (If your computer does not have a CD-ROM drive, you may download the software now.) Follow the setup instructions, clicking "yes" or "next" as each response and then "Finish" to exit the installation program.

Programming your ALRT Med Reminder Model PC100.

  • Remove pull tab from back of the Reminder to activate battery

  • Starting from your desktop, double click on the ALRT Med Reminder Icon. If the Icon did not automatically appear on the desktop, you can create this shortcut by going to Windows Explorer>Program Files>ALRT. Right click on the ALRT icon and left click on Create Shortcut, or drag the icon to your desktop.

  • Both the Instructions and the ALRT Programmer Interface will appear on your screen.

  • First make sure that the programming cable is connected to the Med Reminder and your PC using the serial port programming cable provided. Be certain that your computer is set for the correct time of day. Then follow the programming instructions displayed on the screen.

  • When programming is completed, disconnect the Med Reminder from the programming cable.

  • If, when you attempt to program the Reminder, you encounter the message "THE ALRT MED REMINDER DOES NOT APPEAR TO BE CONNECTED TO ANY OF YOUR COM SERIAL PORT(S). PLEASE CONNECT AND TRY AGAIN" after pressing the "Program the Reminder" button, then it is possible the COM port of your computer is already occupied by a Personal Data Assistant (PDA), such as the Hot Sync Manager for Palm PDA. If so, you may temporarily disengage this feature from the COM port by right clicking your cursor on the Hot Sync Manager icon located on the task bar in the lower right hand corner of your screen and then clicking "Exit." This will free up the occupied COM port and allow you to continue the ALRT PC100 programming routine. The Hot Sync Manager can be re-started from the Palm Desktop program group on the start menu.

  • The Med Reminder will now sound an alert with an audio beeping sound and a blinking light at the programmed time(s) every day.

Press the "ALRT" button when the alert sounds. This will silence the alarm.

Acknowledging the Reminder Alert and Silencing the Alarm
When the alarm sounds press "ALRT" button to silence the alarm. (Unit responds with a number of beeps corresponding to the number of daily reminder events for which it is set). Take the appropriate medication.

Clearing or Reprogramming Set Reminder Alerts
Reconnect the programming cable to the Med Reminder, double click on the ALRT Med Reminder Icon on your desktop, and follow the instructions on the screen for entering reminder event times or by clicking "Erase Reminder".

Additional Features:

  • Acknowledging a Missed Alert Reminder: If you do not hear the reminder alarm when it sounds, the light will continue to blink indefinitely and the alarm will sound the alert for 30 seconds every 10 minutes (every 15 minutes after the first hour). This will continue until you press the "ALRT" button, which will sound the alarm again. Then press the "ALRT" button again to acknowledge the event.

  • The Switch on the side of the Med Reminder: The switch has two positions, "Norm" (Normal) and "Act" (Activate). The switch is used only for the early activation feature (see below). It should be left in the "Norm" position except when being used for early activation.

  • Early Activation: You may activate a reminder event before its scheduled time. Move the switch on the side to the "Act" position and then press and hold the "ALRT" button, and while holding it down, move the switch back to the "Norm" position and then release the "ALRT" button. The Reminder will now sound the alert. Acknowledge and silence the alarm by pressing the "ALRT" button. At this point the Reminder will automatically skip the next timing of this event and revert to its original settings.

Batteries:

Batteries are included and are replaceable. Battery life will vary depending on usage. Upon replacing batteries, the reminder times will need to be reset.

Revised instructions for changing batteries:

The ALRT Med Reminder contains two Alkaline Cell Batteries # LR44. To replace the batteries, loosen small center screw on back of Reminder and remove the small cover. Remove the old batteries and insert the new batteries with the larger flat side of both batteries away from the spring; then replace cover and tighten screw. The Reminder is now ready to be reset with reminder time(s).

The ALRT Med Reminder should be used as a supplement for remembering to take or administer medication on time, and should not be relied upon solely. Avoid prolonged exposure of this product to temperatures below freezing or above 140° F.

Warranty:

ALRT Med Reminder is backed by a 12 MONTH WARRANTY excluding batteries: In the unlikely event that your ALRT Med Reminder malfunctions, during the first 12 months of use, return it along with your Dated Receipt and your Name and Address to: ALRT Warranty Center, PO Box 15379, Winston-Salem, NC 27113. We will replace your ALRT Med Reminder with a new one.

Our Company  |  Contact Us  |  Remote Monitoring